Encapsulation
(5)
Multiple choices
Packaging
(5)
Multiple choices
Model/Brand/Package
Category/Description
Inventory
Price
Data
  • Brand: Wieland
    Encapsulation:
    Category: Safety type
    Description: SNO 4062K Safety relay, dual channel LED indication, used for providing automatic restart function of power supply voltage and safety circuit. Contact rated current: 6A in accordance with BS EN 60204 Part 1 1993; EN 954-1; IEC 204-1; VDE 0113 size (mm): H 96.5, W 22.5, L 114 # # # Note stock number 321-9077 has a monostable anti bounce function and sensor for fast touch applications. Equipped with a soft reset function, it allows the device to perform a local reset in the event of a brief interruption. ###Recognize CCC # # # safety relay
    1672
    1+
    $3229.8849
    10+
    $3200.5223
    25+
    $3185.8410
    50+
    $3171.1597
    100+
    $3156.4784
    150+
    $3141.7971
    250+
    $3127.1158
    500+
    $3112.4345
  • Brand: Wieland
    Encapsulation:
    Category: Safety type
    Description: SNA 4063K Safety relays are used for all equipment, including elevators and heaters. They comply with Class 0, EN 60204-1, and can be applied up to Class 4, EN 954-1 to SIL 3. They comply with EN62061, PL e, and EN13849-1. They can be used as emergency stops or safety door monitors. Through self-monitoring on each on-off cycle, they can be manually reset and cross monitored. One or two channels are wired. External equipment monitoring (EDM) LED indicators are used. TUV and cULus are recognized. Safety relays are available
    9353
  • Category: Safety type
    Description: Wieland SNO 4083KM Safety Relay SNO 4083KM Safety Relay Function - After applying power voltage to terminal A1/A2 and closing the safety input, the current path (normally open contact) is enabled to close and the signal current path (normally closed contact) can be automatically or opened by pressing the reset button (manual monitoring start). When the safety input is turned on/off, the current path (normally open contact) will immediately open and the signal current path (normally closed contact) will close. The SNO 4083KM safety relay requires fewer connecting cables, whether for operations with or without cross monitoring. The dual channel control of SNO 4083KM is executed by a combination of normally closed/normally closed or normally closed/normally open safety sensors. In the case of dual channel control equipment, the synchronization time between the two channels will be automatically monitored. The safety start function can be used together with manual start, which will automatically reset the input for edge monitoring of rising and falling signals. The monostable trigger function is integrated into the safety relay to prevent equipment interlocking in any situation. The intelligent display system displays the different working modes of safety relays in different applications for users, thus enabling simple diagnosis. Emergency stop monitoring, safety doors, and light barriers application stop category 0, compliant with EN 60204-1 single channel or dual channel control dual channel control, with normally closed/normally closed or normally closed/normally open manual or automatic start cross monitoring synchronous time monitoring, used for dual channel control 3 enable current paths/1 signal current path screw terminal, insertable highest PL e/4 class (EN ISO 13849-1) highest SILCL 3 (EN 62061) # # # recognized CCC # # # safety relay
    6098
    1+
    $1961.7136
    10+
    $1943.8798
    25+
    $1934.9630
    50+
    $1926.0461
    100+
    $1917.1292
    150+
    $1908.2123
    250+
    $1899.2954
    500+
    $1890.3786
  • Brand: Wieland
    Encapsulation:
    Category: Safety type
    Description: SNZ 4052K Safety relay, for dual hand control, type IIIC, all devices comply with BS EN 60204 Part 1 1993; EN 954-1; IEC 204-1; VDE 0113. All device dimensions (mm): H 96.5, W 22.5, L 114, contact rating: 6A (all devices). The colors provided may differ from what is displayed. Stop type 0 LED indicator, used for simultaneous inspection of power supply voltage and safety circuit # # # Approved CCC # # Safety relay
    1439
  • Brand: Wieland
    Encapsulation:
    Category: Safety type
    Description: SNA 4043K Safety relays are used for all equipment, including elevators and heaters. They comply with Class 0 EN 60204-1 and can be applied up to Class 4 EN 954-1 or SIL 3 respectively. They comply with EN 62061, PL e EN 13849-1 and can be used as emergency stop or safety door monitors. Each device provides manual or automatic reset and cross monitoring. One or two channels are wired. External equipment monitoring (EDM) LED indication. TUV and cULus are recognized. Safety relays are available
    6391
    1+
    $2051.3262
    10+
    $2032.6778
    25+
    $2023.3536
    50+
    $2014.0294
    100+
    $2004.7052
    150+
    $1995.3809
    250+
    $1986.0567
    500+
    $1976.7325

©Copyright 2013-2025 ICGOODFIND (Shenzhen) Electronics Technology Co., Ltd.

Scroll

Comparison

Unfold

pk

Clear